Technoleg Aml Busbar
Gwell trapio golau a chasglu cyfredol i wella allbwn pŵer modiwl a dibynadwyedd.
Llai o Golled Mannau Poeth
Dyluniad trydanol wedi'i optimeiddio a cherrynt gweithredu is ar gyfer llai o golled mannau poeth a gwell cyfernod tymheredd.
Ymwrthedd PID
Gwarant perfformiad Gwrth-PID ardderchog trwy broses gynhyrchu màs wedi'i optimeiddio a rheoli deunyddiau.
Gwydnwch yn Erbyn Amodau Amgylcheddol Eithafol
Niwl halen uchel ac ymwrthedd amonia.
Llwyth Mecanyddol Gwell
Ardystiedig i wrthsefyll: llwyth gwynt (2400 Pascal) a llwyth eira (5400 Pascal).
Gwarant Cynnyrch 12 Mlynedd
Gwarant Pŵer Llinol 25 Mlynedd
0.55% Diraddio Blynyddol Dros 25 mlynedd
Cyfluniad Pecynnu | |
( Dau baled = Un pentwr ) | |
31pcs/paledi, 62pcs/stack, 682pcs/40'HQ Cynhwysydd | |
Nodweddion Mecanyddol | |
Math Cell | Mono PERC 166 × 166mm |
Nifer y celloedd | 144 (6×24) |
Dimensiynau | 2096×1039×35mm (82.52×40.91×1.38 modfedd) |
Pwysau | 25.1kg (55.34 pwys) |
Gwydr Blaen | 3.2mm, Gorchudd Gwrth-fyfyrio, Trosglwyddiad Uchel, Haearn Isel, Gwydr Tymherus |
Ffrâm | Aloi Alwminiwm Anodized |
Blwch Cyffordd | IP68 Gradd |
Ceblau Allbwn | TUV 1 × 4.0mm2 (+): 290mm, (-): 145mm neu Hyd Wedi'i Addasu |
MANYLION | ||||||||||
Math Modiwl | ALM435M-72HLM ALM435M-72HLM-V | ALM440M-72HLM ALM440M-72HLM-V | ALM445M-72HLM ALM445M-72HLM-V | ALM450M-72HLM ALM450M-72HLM-V | ALM455M-72HLM ALM455M-72HLM-V | |||||
STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | STC | NOCT | |
Pwer Uchaf (Pmax) | 435Wp | 324Wp | 440Wp | 327Wp | 445Wp | 331Wp | 450Wp | 335Wp | 455Wp | 339Wp |
Foltedd Pwer Uchaf (Vmp) | 40.77V | 37.76V | 40.97V | 37.89V | 41.17V | 38.10V | 41.37V | 38.31V | 41.56V | 38.47V |
Uchafswm Pŵer Cerrynt (Imp) | 10.67A | 8.57A | 10.74A | 8.64A | 10.81A | 8.69A | 10.88A | 8.74A | 10.95A | 8.80A |
Foltedd cylched agored (Voc) | 48.67V | 45.84V | 48.87V | 46.03V | 49.07V | 46.22V | 49.27V | 46.41V | 49.46V | 46.59V |
Cerrynt cylched byr (Isc) | 11.32A | 9.14A | 11.39A | 9.20A | 11.46A | 9.26A | 11.53A | 9.31A | 11.60A | 9.37A |
STC Effeithlonrwydd Modiwl (%) | 19.97% | 20.20% | 20.43% | 20.66% | 20.89% | |||||
Tymheredd Gweithredu (℃) | 40 ℃ ~ + 85 ℃ | |||||||||
Foltedd System Uchafswm | 1000/1500VDC (IEC) | |||||||||
Graddfa Ffiws Gyfres Uchaf | 20A | |||||||||
Goddefgarwch Pŵer | 0~+3% | |||||||||
Cyfernodau Tymheredd Pmax | -0.35% / ℃ | |||||||||
Cyfernodau Tymheredd Voc | -0.28% / ℃ | |||||||||
Cyfernodau Tymheredd Isc | 0.048% / ℃ | |||||||||
Tymheredd Cell Weithredu Enwol (NOCT) | 45 ± 2 ℃ |
STC: Arbelydru 1000W/m2 AM=1.5 Tymheredd Cell 25°C AM=1.5